Adjustment |
| |
- If door is hard to operate in both directions
- Door is out of plumb. Loosen the two bolts on the cam at the top
of the door, shim the door out until plumb using 1/16" plastic
shims supplied with the door and re-tighten the bolts.
- If door is hard to operate in one direction
- Cam or bottom bearing is not square or level and is binding on
shaft. Loosen cam and bottom bearing bolts. Allow door to reseat
and tighten bolts.
- Cam holes not level. Lift door off cam using spacer block. Loosen
cam bolts, lift cam on side of door that would not close and tighten
bolts.
- If door does not fully close
- Bottom air seal is dragging. Hold air seal using needle nose pliers
and trim and trim with razor knife to floor contour.
- If doors do not meet in center or single door does not close in
one direction only
- Confirm absence of wind or negative air pressure at opening. If
not, jambs are not parallel. Use half-shims behind one side of cam
to align each door.
Next Step 4
|